We are known as one of the leading manufacturers and suppliers of heavy-duty Air Cooled Diesel Engine Generators that are commonly used on constructional as well as industrial sites to produce electricity using fuel energy. The generator installed within these machines is provided with commutators to transform electrical from DC to AC. The direct coupling between the generator and flywheel ensures low power loss. Air Cooled Diesel Engine Generators offered by us are also provided with an oil filter unit to eliminate solid impurities from diesel that ensures high combustion efficiency. Buyers can get these power converters from us at a reasonable and low price range.

Air Cooled Single Cylinder Engine Generators

  • Alternator Brushless, Self-excited
  • Bore *Stroke 68 mm 54 mm
  • Color Red/Black
  • Dimension (L*W*H) 590 430 520 mm
  • Engine Model 168F
  • Engine Type Other, Air Cooled, 4-Stroke, Single Cylinder
  • Fuel Consumption 1.7 L/h (at 75% load)
  • Fuel Tank Capacity 15 Litres
  • Insulation Class F
  • Noise Level 70 dB(A) @7m
  • Output Type AC Single Phase
  • Phase Single Phase
  • Poles Number 2
  • Power Range 2 kVA 2.8 kVA
  • Pressure 8.5 Bar
  • Product Type Air Cooled Single Cylinder Engine Generator
  • Protection Class IP23
  • Rated Frequency 50 Hz
  • Rated Power 2.5 kVA
  • Rated Voltage 220V
  • Starting Type Other, Recoil/Electric Start
  • Weight 48 kg

Stockpile on our years of expertise, we are offering our precious customers a vast array of Air Cooled Single Cylinder Engine Generators to our clients. This machinery is utilized in the agro sectors. It requires a constant power-supply. The entire offered items are tested on the various quality parameters before final dispatch. Our provided Single Cylinder Engine Generators is high in quality and durability. Our clients can avail this from us at fixed price rate.

Stockpile on our years of expertise, we offer our precious customers a vast array of Air-Cooled Single Cylinder Engine Generators to our clients. This machinery is utilized in the agro sectors. It requires a constant power supply. The entire offered items are tested on the various quality parameters before final dispatch. Our provided Single Cylinder Engine Generators is high in quality and durability. Our clients can avail of this from us at a fixed price rate. The offered Air-Cooled Single Cylinder Engine Generators are alternatively marketed in different specifications to fulfill the customer demands inside a small budget.  

Product Details


KVA

KW

AMP.

BHP

PHASE

2.2

2.2

6

4

1

4

4

10

6.5 (85

1

5

5

18

8 (87.5)

1

5

5

20

8 (95)

1

6

6

24

1095

1

6

6

24

10 (102)

1

7

7

28

12 (102)

1

7.5

7.5

30

14 (114.3)

1



Efficient Forced Air Cooling System

Designed with a forced air-cooled mechanism, this generator ensures effective thermal management during operation. The airflow system prevents overheating even under extended use, protecting engine components and maintaining optimal performance. This feature significantly reduces maintenance needs and prolongs the engine's lifespan.


Reliable Power and Voltage Regulation

Equipped with capacitor-based voltage regulation, the generator maintains steady output within a 5% tolerance, safeguarding electrical devices from voltage fluctuations. Its brushless, self-excited alternator delivers consistent power, making it suitable for sensitive appliances in homes and commercial setups. With single phase AC output, it provides versatility and stability.


User-Friendly and Versatile Applications

This generator's recoil and key start options offer flexibility and ease of use for diverse settings including homes, shops, and mobile food carts. Its extended running time of 9 hours at 50% load, compact dimensions, and EURO II compliance make it a reliable, eco-friendly choice for outdoor activities, business continuity, and emergency backup power.

FAQ's of Air Cooled Single Cylinder Engine Generators:


Q: How does the forced air cooling system enhance the generator's performance?

A: The forced air cooling system circulates air around the engine to dissipate heat efficiently, preventing overheating during prolonged use. This helps maintain optimal operating temperature, reduces wear, and extends the engine's lifespan, improving overall reliability and reducing maintenance.

Q: What applications are ideal for this air-cooled single cylinder generator?

A: This generator is well-suited for homes, shops, mobile food carts, and outdoor use such as events or camping. Its portability, low noise level, and stable power output make it versatile for both residential and commercial needs, providing dependable electricity wherever required.

Q: When should the oil be changed in the generator, and what lubrication system does it use?

A: Oil should typically be checked before each use and changed according to the manufacturer's maintenance schedule, especially after extended running periods. The generator uses a splash lubrication system, distributing oil throughout the engine to minimize friction and wear for smooth operation.

Q: Where can the generator be installed or used?

A: This generator is designed for outside installation in well-ventilated areas to ensure proper cooling and safety. It can be used in homes, shops, outdoor locations, and mobile setups like food carts, provided it's protected from direct rain and placed on a stable, level surface.

Q: What benefits does capacitor-type voltage regulation provide?

A: Capacitor-type voltage regulation stabilizes the generator's output, keeping voltage fluctuations within 5%. This ensures that connected devices operate safely and efficiently, reducing the risk of damage to sensitive equipment and prolonging their lifespan.

Q: How do I start and operate the generator?

A: The generator offers both recoil (manual) and key (electric) start options. For recoil start, firmly pull the handle; for key start, simply turn the ignition key. Follow the operation manual for setup, fueling, and load connection procedures to ensure safe and efficient use.

Q: What is the fuel capacity and expected running time for this generator model?

A: With a 15-litre fuel tank and fuel consumption rate of 1.7 litres per hour at 75% load, the generator can run continuously for approximately 9 hours at half load. This extended runtime is advantageous during outages or in locations lacking frequent refueling options.

Send Inquiry

Air Cooled Double Cylinder Engine Generators

  • Alternator Standard Alternator
  • Bore *Stroke 100 x 115 mm
  • Color Green
  • Dimension (L*W*H) 1800 x 950 x 1200 mm
  • Engine Model Air Cooled Engine
  • Engine Type Other, Double Cylinder Engine
  • Fuel Consumption 280 g/kWh
  • Fuel Tank Capacity 15 Liters
  • Insulation Class H
  • Noise Level 85 dB
  • Output Type AC
  • Phase Single Phase / Three Phase, Other
  • Poles Number 4 Poles
  • Power Range 5 kVA - 15 kVA
  • Product Type Air Cooled Double Cylinder Engine Generators
  • Protection Class IP23
  • Rated Frequency 50 Hz
  • Rated Power 10 kVA
  • Rated Voltage 230V / 400V
  • Starting Type Electric Start
  • Unit of Measure ,
  • Warranty 12 Months
  • Weight 390 kg

Rocker Bush are physically greased up, and any remaining parts are also sprayed grease. In Air Cooled Double Cylinder Engine Generators, pressure feed is used to gear the lubricating pump to the oil parts, main bearings, and large end bearings. The main bearings are tapper rollers, white aluminum alloy or metal lines, small end connected rod shaft, steel-walled rocker, and other elements integrated with bush bearings. Consistent Speed divergent lead governor is attached on the camshaft gear of our Air-Cooled Double Cylinder Engine Generators. 

Product Details


KVA

KW

AMP.

BHP

PHASE

8

8

40

15 (87.5)

1

10

10

48

18 (95)

1

12

12

56

20 (102)

1

15

15

64

28 (114)

1